Transformers

10kV Three-Dimensional Wound-Core Distribution Transformer

For residential, factory and mining power distribution.

10 kV classWound coreThree Phase
Voltage Class
10 kV
Rated Capacity
30–2,500 kVA
Frequency
50/60 Hz

02 / Key specifications

Check the published ratings

Published product data. Unconfirmed items are omitted.

ParameterPublished value
Electrical ratings
Rated Capacity30 kVA - 2,500 kVA
Frequency50/60 Hz
PhaseThree Phase
Vector GroupDyn11 / Yyn0
Performance
Impedance4% - 6%
Construction
Tap Positions5 positions

03 / Applications & selection

Does it fit your project?

  • Applications. Residential facilities, factories, mining enterprises, airports, stations and schools.
  • Selection. Confirm both voltage values and their units, the core material and insulating-liquid specification before selection. No secondary-voltage value is inferred.
  • Environment. Confirm installation conditions; no enclosure or indoor/outdoor rating is assumed.
Application / installationApproved media pending1600 × 1200px · 4:3
P04 · Application / installation

04 / Construction & options

Confirm the construction

The brochure describes a liquid-immersed transformer with a three-dimensional wound core and a symmetrical three-phase magnetic circuit. The insulating-liquid specification is not identified here.

Options: confirm the required configuration and interfaces before quotation.

Technical Details

A three-dimensional wound core distinguishes this series. Core material and loss-table variant must be selected before specifying losses.

The source prints 6kV–35kVA for primary voltage and 0.4kVA for secondary voltage. Both voltage fields remain empty pending clarification. The core material and loss-table variant must be selected before specifying losses. No project-specific certification, delivered-project reference or public datasheet is claimed. The brochure is a technical source and is not offered for public download.

Conceptual equipment sketch; not a product photograph
P05 · CONCEPTUAL EQUIPMENT SKETCH · Not a product photograph. Final configuration subject to technical confirmation.

05 / Standards, testing & documents

Agree the acceptance basis

  • Standards: ANSI/IEEE, GB 20052-2020, IEC, NEMA. Confirm edition and applicability; not a certification claim.
  • Testing / FAT: request confirmation of routine, type, special tests and witness arrangements.
  • Acceptance: agree required records before ordering; availability remains pending.
Testing / FATApproved media pending1600 × 1200px · 4:3
P06 · Testing / FAT

Technical document status

Project-specific documents and release permission are confirmed against project requirements.

Product Datasheet
Pending Supplier Confirmation
General Arrangement Drawing
Pending Supplier Confirmation
Dimension Drawing
Pending Supplier Confirmation
Interface Drawing
Pending Supplier Confirmation
Test / FAT Report
Pending Supplier Confirmation
Installation / O&M
Pending Supplier Confirmation
Packing Information
Pending Supplier Confirmation
Request Documents ↗

06 / FAQ

Resolve your procurement questions

Does the voltage class confirm the primary voltage?

10 kV is the classification of this series. Both primary and secondary voltage values remain unconfirmed because source units require clarification.

What distinguishes this product construction?

The brochure describes a liquid-immersed transformer with a three-dimensional wound core and a symmetrical three-phase magnetic circuit. The insulating-liquid specification is not identified here.

Are drawings, test records and a datasheet available?

No public product datasheet or project-specific test record is established for this record. Document availability, release permission and any FAT or witness-inspection arrangement require supplier and project confirmation.

What should I include in a quotation request?

Please provide the wound-core transformer capacity, primary and secondary voltages with confirmed units, frequency, vector group, impedance, core-material requirement, insulating-liquid specification and installation conditions. Include the applicable loss basis, quantity and destination.