10kV Amorphous-Alloy Epoxy-Resin Cast Dry-Type Power Transformer
For residential, commercial and industrial electrical systems.
- Voltage Class
- 10 kV
- Rated Capacity
- 30–2,500 kVA
- Secondary Voltage
- 0.4 kV
On this page
02 / Key specifications
Check the published ratings
Published product data. Unconfirmed items are omitted.
| Parameter | Published value |
|---|---|
| Electrical ratings | |
| Rated Capacity | 30 kVA - 2,500 kVA |
| Secondary Voltage | 0.4 kV |
| Frequency | 50/60 Hz |
| Phase | Three Phase |
| Vector Group | Dyn11 / Yyn0 |
| Performance | |
| Impedance | 4% - 6% |
| Construction | |
| Tap Positions | 5 positions |
03 / Applications & selection
Does it fit your project?
- Applications. Residential, commercial and industrial facilities; factory and mining applications are listed in the reviewed source.
- Selection. Confirm primary voltage, specific model, insulation class, cooling designation and installation conditions. Guaranteed losses depend on the selected capacity, temperature and efficiency grade.
- Environment. Confirm installation conditions; no enclosure or indoor/outdoor rating is assumed.
04 / Construction & options
Confirm the construction
The brochure identifies an amorphous-alloy core and epoxy-resin cast construction. This material distinction is retained without transferring the numerical performance claims of other core designs.
Options: confirm the required configuration and interfaces before quotation.
Technical Details
The amorphous-alloy core is the distinguishing material in this cast-resin series. Percentage savings are not stated as guaranteed performance.
The primary-voltage range ends in 35kVA in the source. Specific model, insulation class, cooling designation and guaranteed losses remain unconfirmed. Loss-table values depend on the selected capacity, temperature and efficiency grade; percentage savings are not entered as guaranteed performance. No project-specific certification, delivered-project reference or public datasheet is claimed. The brochure is a technical source and is not offered for public download.
05 / Standards, testing & documents
Agree the acceptance basis
- Standards: ANSI/IEEE, GB 20052-2020, IEC, NEMA. Confirm edition and applicability; not a certification claim.
- Testing / FAT: request confirmation of routine, type, special tests and witness arrangements.
- Acceptance: agree required records before ordering; availability remains pending.
Technical document status
Project-specific documents and release permission are confirmed against project requirements.
06 / FAQ
Resolve your procurement questions
Does the voltage class confirm the primary voltage?
10 kV is the classification of this series. The published secondary voltage is 0.4 kV. Primary voltage requires source clarification and project confirmation.
What distinguishes this product construction?
The brochure identifies an amorphous-alloy core and epoxy-resin cast construction. This material distinction is retained without transferring the numerical performance claims of other core designs.
Are drawings, test records and a datasheet available?
No public product datasheet or project-specific test record is established for this record. Document availability, release permission and any FAT or witness-inspection arrangement require supplier and project confirmation.
What should I include in a quotation request?
Please provide the amorphous-alloy cast-resin transformer capacity, confirmed voltage requirements, frequency, vector group, impedance and application. Specify insulation, ventilation, enclosure and loss-evaluation requirements, and include quantity and destination.
07 / Project RFQ
Request project pricing
10kV Amorphous-Alloy Epoxy-Resin Cast Dry-Type Power Transformer
Please provide the amorphous-alloy cast-resin transformer capacity, confirmed voltage requirements, frequency, vector group, impedance and application. Specify insulation, ventilation, enclosure and loss-evaluation requirements, and include quantity and destination.